Team:HKUST/Protocols/Agarose gel
From 2009.igem.org
(Difference between revisions)
Line 54: | Line 54: | ||
<div class="contentxx"> | <div class="contentxx"> | ||
- | <p> | + | <p>Agarose gel preparation and gel electrophoresis</p> |
- | <p> Purpose: To check the result </p | + | <p> Purpose: To check the result </p> |
Materials: Agarose, 0.5X TBE, SYBR safe DNA gel stain, DNA loading dye, DNA ladder/marker <br><br> | Materials: Agarose, 0.5X TBE, SYBR safe DNA gel stain, DNA loading dye, DNA ladder/marker <br><br> | ||
Choice of ladders: VC100bp Plus DNA ladder (highest band 3000bp); Lamda DNA BstEII marker (highest band 8400bp, 1% argarose) <br><br> | Choice of ladders: VC100bp Plus DNA ladder (highest band 3000bp); Lamda DNA BstEII marker (highest band 8400bp, 1% argarose) <br><br> | ||
<p>Procedure: </p> | <p>Procedure: </p> | ||
- | + | 1. To make a 0.8% agarose gel, use 0.16 g agarose per 20 mL 0.5x TBE. <br><br> | |
- | + | 2. Cover the flask with plastic wrap to prevent boiling over, then microwave the solution for 1-2 minutes to dissolve the agarose. <br><br> | |
- | **Let agarose solution cool for 5 minutes, then add SYBR safe DNA gel stain to a final concentration of 0.5 μg/mL. | + | **Let agarose solution cool for 5 minutes, then add SYBR safe DNA gel stain to a final concentration of 0.5 μg/mL. <br><br> |
- | **Pour the agarose solution into a casting tray with well comb in place. Allow 20-30 minutes to completely solidify. | + | **Pour the agarose solution into a casting tray with well comb in place. Allow 20-30 minutes to completely solidify.<br><br> |
- | **Place the agarose gel into the gel box and fill the box with 0.5X TBE until the gel is immersed. | + | **Place the agarose gel into the gel box and fill the box with 0.5X TBE until the gel is immersed.<br><br> |
- | **Load an appropriate molecular weight ladder into the first lane of the gel. If needed, an additional ladder with different molecular weight could be loaded into the last lane. | + | **Load an appropriate molecular weight ladder into the first lane of the gel. If needed, an additional ladder with different molecular weight could be loaded into the last lane.<br><br> |
- | **Add 1 μL loading dye per 5 μL of sample. | + | **Add 1 μL loading dye per 5 μL of sample.<br><br> |
- | **Load the samples from left to right. | + | **Load the samples from left to right.<br><br> |
- | **Cover the gel box and plug in the electrodes in a way that the samples will run towards the positive, red electrode. | + | **Cover the gel box and plug in the electrodes in a way that the samples will run towards the positive, red electrode.<br><br> |
- | **Run the gel at 100V until the dye line is approximately 50-75% of the way down the gel. Approximately 20-30 minutes. | + | **Run the gel at 100V until the dye line is approximately 50-75% of the way down the gel. Approximately 20-30 minutes.<br><br> |
- | **Carefully remove the gel from the gel box and check the result under UV exposure. | + | **Carefully remove the gel from the gel box and check the result under UV exposure.<br><br> |
*Tips: | *Tips: | ||
- | **Higher concentration of agarose solution makes better resolution for less molecular weight expected band. | + | **Higher concentration of agarose solution makes better resolution for less molecular weight expected band.<br><br> |
- | **Let bottom of the flask be immersed in a cup of cold water for faster cooling. | + | **Let bottom of the flask be immersed in a cup of cold water for faster cooling.<br><br> |
- | **In order for clearer band to cut specific band on the gel, immerse the gel in Ethidium bromide for 10-15 minutes after step k. | + | **In order for clearer band to cut specific band on the gel, immerse the gel in Ethidium bromide for 10-15 minutes after step k.<br><br> |
*Safety tips: | *Safety tips: | ||
- | **Be sure to wear a glove before treating the hot flask. | + | **Be sure to wear a glove before treating the hot flask.<br><br> |
- | **Ethidium bromide is a strong mutagen. Wear a lab coat, eye protection, and gloves when working with this chemical. | + | **Ethidium bromide is a strong mutagen. Wear a lab coat, eye protection, and gloves when working with this chemical. <br><br> |
Revision as of 09:08, 18 October 2009
a
Agarose gel preparation and gel electrophoresis
Purpose: To check the result
Materials: Agarose, 0.5X TBE, SYBR safe DNA gel stain, DNA loading dye, DNA ladder/markerChoice of ladders: VC100bp Plus DNA ladder (highest band 3000bp); Lamda DNA BstEII marker (highest band 8400bp, 1% argarose)
Procedure:
1. To make a 0.8% agarose gel, use 0.16 g agarose per 20 mL 0.5x TBE.2. Cover the flask with plastic wrap to prevent boiling over, then microwave the solution for 1-2 minutes to dissolve the agarose.
**Let agarose solution cool for 5 minutes, then add SYBR safe DNA gel stain to a final concentration of 0.5 μg/mL.
**Pour the agarose solution into a casting tray with well comb in place. Allow 20-30 minutes to completely solidify.
**Place the agarose gel into the gel box and fill the box with 0.5X TBE until the gel is immersed.
**Load an appropriate molecular weight ladder into the first lane of the gel. If needed, an additional ladder with different molecular weight could be loaded into the last lane.
**Add 1 μL loading dye per 5 μL of sample.
**Load the samples from left to right.
**Cover the gel box and plug in the electrodes in a way that the samples will run towards the positive, red electrode.
**Run the gel at 100V until the dye line is approximately 50-75% of the way down the gel. Approximately 20-30 minutes.
**Carefully remove the gel from the gel box and check the result under UV exposure.
*Tips: **Higher concentration of agarose solution makes better resolution for less molecular weight expected band.
**Let bottom of the flask be immersed in a cup of cold water for faster cooling.
**In order for clearer band to cut specific band on the gel, immerse the gel in Ethidium bromide for 10-15 minutes after step k.
*Safety tips: **Be sure to wear a glove before treating the hot flask.
**Ethidium bromide is a strong mutagen. Wear a lab coat, eye protection, and gloves when working with this chemical.