Team:Freiburg bioware/Human Practice/Safety

From 2009.igem.org

(Difference between revisions)
 
Line 124: Line 124:
<div style="text-align: center;"></div>
<div style="text-align: center;"></div>
<br />
<br />
-
<p>About: Safety in the Lab<br />
+
<p><H4>About: Safety in the Lab </H4></br><br>
</p>
</p>
-
<p>1.Would any of our project ideas raise safety issues in terms
+
<p><b>1.Would any of our project ideas raise safety issues in terms
of:<br />
of:<br />
</p>
</p>
<p>-researcher safety,<br />
<p>-researcher safety,<br />
-public safety, or<br />
-public safety, or<br />
-
-environmental safety?<br />
+
-environmental safety?<br /></b>
</p>
</p>
<p>Standards for a Security Level 1 lab:<br />
<p>Standards for a Security Level 1 lab:<br />
Line 138: Line 138:
according to the Gentechnikgesetz (law for gene technology). This means
according to the Gentechnikgesetz (law for gene technology). This means
that the lab conforms to standards that our instructors introduced us
that the lab conforms to standards that our instructors introduced us
-
to in the beginning of the project in April 2009. After a safety
+
to at the beginning of the project in April 2009. After a safety
briefing for the group, we had a &ldquo;safety-tour&rdquo;
briefing for the group, we had a &ldquo;safety-tour&rdquo;
through the lab while
through the lab while
-
our advisor Kristian told us how to handle the different instruments
+
our adviser Kristian told us about the different chemicals we would be using, how to handle genetically modified bacteria and how to operate the different instruments
-
like centrifuges and Bunsen burners and showed us were to find the fire
+
like centrifuges and Bunsen burners. Furthermore, he showed us where to find the fire
-
extinguishers, safety showers and eye showers and explained the
+
extinguishers, safety showers and eye showers and explained their
-
handling. In the lab we store highly inflammable materials and gas
+
handling. In the lab, we store highly inflammable materials and gas
containers in a safety cabinet.
containers in a safety cabinet.
When we were working with hazardous chemicals or genetically modified
When we were working with hazardous chemicals or genetically modified
Line 151: Line 151:
We disinfected our hands, the pipettes and the bench before and after
We disinfected our hands, the pipettes and the bench before and after
working with bacteria and phages. Most of the material we use in the
working with bacteria and phages. Most of the material we use in the
-
lab has to be sterile and it went through the autoclave before and
+
lab has to be sterile and was autoclaved before using. All the bacteria waste as well as all consumable that had been in contact with bacteria were collected in autoclave bags or containers and
-
after using. All the bacteria waste was collected in autoclave bags and
+
autoclaved before delivered to the waste containers to prevent an
autoclaved before delivered to the waste containers to prevent an
-
environmental pollution.
+
environmental contamination.
-
While working with toxic stuff or reagents that are harmful to health
+
While working with toxic stuff or reagents that are harmful to health,
-
we additionally used the hood as working station. When using liquid
+
we additionally used a hood as working station. When using liquid
-
nitrogen or working with UV-light we were wearing safety glasses and
+
nitrogen or working with UV-light, we were wearing safety glasses and
-
gloves and handled our reagents with care.<br />
+
gloves and handled our reagents with care.<br /><br>
</p>
</p>
-
<p>2. Is there a local biosafety group, committee, or review
+
<p><b>2. Is there a local biosafety group, committee, or review
-
board at your institution?<br />
+
board at your institution?</b><br />
</p>
</p>
-
<p>In Germany we have by law a safety officer in each lab/working
+
<p>In Germany, we have by law a safety officer in each lab/working
-
group who controls their work and notes.<br />
+
group who controls the work as well as the lab notes.<br /><br>
</p>
</p>
-
<p>3. What does your local biosafety group think about your
+
<p><b>3. What does your local biosafety group think about your
-
project?<br />
+
project?</b><br />
</p>
</p>
-
<p>We made sure to follow all regulations described by the
+
<p>We made sure to follow all regulations described in the
Gentechnikgesetz (law for gene technology) including the
Gentechnikgesetz (law for gene technology) including the
Gentechnik-Sicherheitsverordnung-GenTSV (gene technology
Gentechnik-Sicherheitsverordnung-GenTSV (gene technology
Line 176: Line 175:
Gentechnik-Verfahrensverordnung-GenTVfV (gene technology proceeding
Gentechnik-Verfahrensverordnung-GenTVfV (gene technology proceeding
regulation).
regulation).
-
Thus we classified our work as safety-level one work.<br />
+
Thus, we classified our work as safety-level one work.<br /><br>
</p>
</p>
-
<p>4. Do any of the new BioBrick parts that you made this year
+
<p><b>4. Do any of the new BioBrick parts that you made this year
-
raise any safety issues?<br />
+
raise any safety issues?</b><br />
</p>
</p>
-
No, the E. coli strains with which we did our experiments have
+
No, the <i>E. coli</i> strains, which we used for our experiments, have
-
been deactivated, so that they aren&rsquo;t anymore able to cause
+
been deactivated, so that they aren&rsquo;t anymore able to cause any contamination.
-
diseases.
+
Importantly, the <i>E. coli</i> strains we used are all non-pathogenic and non-adherent strains. The genes we
-
The E.coli strains are non pathogenic and non adherent. The genes we
+
cloned are coding for non-toxic and non-pathogenic proteins.
-
clone are coding for non toxic and non pathogenic proteins.
+
</div>
</div>
<div class="cleared"></div>
<div class="cleared"></div>

Latest revision as of 21:42, 21 October 2009

FREiGEM


About: Safety in the Lab



1.Would any of our project ideas raise safety issues in terms of:

-researcher safety,
-public safety, or
-environmental safety?

Standards for a Security Level 1 lab:

The lab where our iGEM team works, is a security level 1 lab according to the Gentechnikgesetz (law for gene technology). This means that the lab conforms to standards that our instructors introduced us to at the beginning of the project in April 2009. After a safety briefing for the group, we had a “safety-tour” through the lab while our adviser Kristian told us about the different chemicals we would be using, how to handle genetically modified bacteria and how to operate the different instruments like centrifuges and Bunsen burners. Furthermore, he showed us where to find the fire extinguishers, safety showers and eye showers and explained their handling. In the lab, we store highly inflammable materials and gas containers in a safety cabinet. When we were working with hazardous chemicals or genetically modified organisms we were wearing suitable protection gear such as lab coat, safety glasses and gloves. We disinfected our hands, the pipettes and the bench before and after working with bacteria and phages. Most of the material we use in the lab has to be sterile and was autoclaved before using. All the bacteria waste as well as all consumable that had been in contact with bacteria were collected in autoclave bags or containers and autoclaved before delivered to the waste containers to prevent an environmental contamination. While working with toxic stuff or reagents that are harmful to health, we additionally used a hood as working station. When using liquid nitrogen or working with UV-light, we were wearing safety glasses and gloves and handled our reagents with care.

2. Is there a local biosafety group, committee, or review board at your institution?

In Germany, we have by law a safety officer in each lab/working group who controls the work as well as the lab notes.

3. What does your local biosafety group think about your project?

We made sure to follow all regulations described in the Gentechnikgesetz (law for gene technology) including the Gentechnik-Sicherheitsverordnung-GenTSV (gene technology safety-regulation), the Gentechnik-Aufzeichnungsverordnung-GenTAufzV (gene technology recording regulation) and the Gentechnik-Verfahrensverordnung-GenTVfV (gene technology proceeding regulation). Thus, we classified our work as safety-level one work.

4. Do any of the new BioBrick parts that you made this year raise any safety issues?

No, the E. coli strains, which we used for our experiments, have been deactivated, so that they aren’t anymore able to cause any contamination. Importantly, the E. coli strains we used are all non-pathogenic and non-adherent strains. The genes we cloned are coding for non-toxic and non-pathogenic proteins.