'''Hydrogen lamp''' | '''Hydrogen lamp''' | ||
+ | The Balmer lamp provided a narrower band of wavelength, we hoped that it can characterise the E.coli system better than borad spectrum light | ||
By using a hydrogen lamp that has a limited wavelength, the gene expression should | By using a hydrogen lamp that has a limited wavelength, the gene expression should | ||
Filter paper | Filter paper |
Revision as of 14:41, 10 October 2009
Home | Team | Project | Parts | Modeling | Notebook |
---|
Overall projectIn this project, we originally intended to create an E.coli system that is sensitive to multiple wavelengths of light and produce a colour indication of the specific wavelength it is exposed to. However due to limitations in the time and number of people available, and due to unexpected results the project changed significantly.
Project DetailsThe first experiment we carried to familiarise ourselves with the strain, was to repeat the light sensing ability of RU1012 as described in the Levskaya et al. paper[1], in its most simple form. Red light switch off the photoreceptor through inhibiting autophosphorylation, and therefore switching off the expression for Lac Z production. We shown borad spectrum light on one sample and kept the other in the dark so that gene expression can not be interefered. The samples were put on seperate agar plates with X-gal on it which acts as a substrate for Lac Z and producing a blue colouration. To our surprise, the result were opposite to what we expected: the illuminated plate produced more pigment than the one in the dark, whereas it should have been the opposite. The same experiment was repeated to confirm that the result was systematic. Later on we realise that the wavelength that inhibits the autophosphorylation has to be a specific wavelength, a broadspectrun light that contains that wavelength does not have the same effect. Too solve that problem we have tried various measures:
The Balmer lamp provided a narrower band of wavelength, we hoped that it can characterise the E.coli system better than borad spectrum light By using a hydrogen lamp that has a limited wavelength, the gene expression should Filter paper Varying light intensity
After that, the results were analyzed and compared with the models. ResultsDiscussionFurther WorkDue to time restrictions, and the few people we had available for this project. We would to continue characterising the parts of this system, as well as repeat our the Miller assay for more values of light intensities and wavelengths. We also have the thought of new directions to develop the project after contacting Christopher A. Voigt. ReferencesPapers
|