Team:HKU-HKBU/Motor Preliminary Trials

From 2009.igem.org

(Difference between revisions)
(Membrane Version)
(Preliminary test using a Membrane)
Line 3: Line 3:
{{Team:HKU-HKBU/header}}
{{Team:HKU-HKBU/header}}
-
==Preliminary test using a Membrane==
+
==Binding performance test using a membrane==
-
We used Immobilon-P transfer membrane to evaluate the performance of streptavidin-biotin binding of bacteria onto a surface. Before cutting down the membrane into small pieces, pre-activation should be applied to it first [Link 1]. After the pre-activation, the membrane was first sheared into strings manually by using scissors, with the width and thickness both around 100μm. Then, we used Leica-crytomicrotome to cut the “threads” into small fragments, with the length of 60μm. Thus, we got the motors, whose demention was aproximately 100μm×60μm×100μm. Since the surface of membrane had already been activated, the polar-expression bacteria could bind onto such biotin-coated motors.  
+
We used Immobilon-P transfer membrane to evaluate the performance of streptavidin-biotin binding of bacteria onto a surface. Before cutting apart the membrane into small pieces, pre-activation should be applied to it first [Link 1]. After the pre-activation, the membrane was first sheared into strings manually by using scissors, with the width and thickness being approximately 100μm. We then used Leica-crytomicrotome to cut the “threads” into even smaller fragments, with the length of which being 60μm. A binding performance testing device demension was aproximately 100μm×60μm×100μm. Since the surface of membrane had already been activated, the polar-expression bacteria could bind onto such biotin-coated motors.  
{{Team:HKU-HKBU/footer}}
{{Team:HKU-HKBU/footer}}

Revision as of 18:37, 20 October 2009

Binding performance test using a membrane

We used Immobilon-P transfer membrane to evaluate the performance of streptavidin-biotin binding of bacteria onto a surface. Before cutting apart the membrane into small pieces, pre-activation should be applied to it first [Link 1]. After the pre-activation, the membrane was first sheared into strings manually by using scissors, with the width and thickness being approximately 100μm. We then used Leica-crytomicrotome to cut the “threads” into even smaller fragments, with the length of which being 60μm. A binding performance testing device demension was aproximately 100μm×60μm×100μm. Since the surface of membrane had already been activated, the polar-expression bacteria could bind onto such biotin-coated motors.

Sponsors