Team:IIT Bombay India/CAM
From 2009.igem.org
Pranayiitb (Talk | contribs) (→Control Theory Approach to Study Multiple Feedbacks in Lac-operon system) |
Pranayiitb (Talk | contribs) |
||
Line 136: | Line 136: | ||
6. In presence of external noise, the multiple-feedback system attenuates noise at the output better than open-loop system. | 6. In presence of external noise, the multiple-feedback system attenuates noise at the output better than open-loop system. | ||
- | + | A detailed review of all the Control analysis modelling attempted is available [[Media:Control modelling.pdf|here]]. | |
| | | | ||
|} | |} |
Revision as of 23:58, 21 October 2009
Home | The Team | The Project | Analysis | Modeling | Notebook | Safety |
---|
Control Theory Approach to Study Multiple Feedbacks on Lac-operon |
Control Analysis Model
1. Characterize the system. 2. Linearize the system around a set-point on LacI. 3. Obtain a linear model in transfer-function (s) domain. 4. Frequency response analysis using magnitude and phase bode plots. 5. Sensitivity analysis using magnitude bode plot for sensitivity function. 6. Steps 2-5 for 1000μM IPTG. 7. Add external noise in the system and tried to determine the reduction in the noise for the system with multiple feedbacks and open-loop system.
We have 2 control levels. By combination, we have 4 different control loops or structures possible, expressed in 4 different strains. They are as follows:- Strain 1 (Open loop) with plasmid (BBa_K255004) It has got open loop without any feedback.re there is constitutive expression of LacI.
It has got a single negative feedback loop. So the expression of LacI is under regulation. Here also the copy number of the plasmid is fixed.
It has got a single negative feedback loop on the feedback copy number. Here there is no control on the LacI expression.
It has dual negative feedback loop one on the plasmid copy number and second on the LacI expression.
The linearized system in transfer-function (s) domain is as given below:
The magnitude and phase bode plots for the system is given below: Fig: Magnitude, phase and sensitivity bode plots for LacI system given in linear model. The green line represents CFS with only C1(s), while blue line represents DFS with both C1(s) and C2(s). The gain margin for both CFS and DFS is ∞. The phase margin is 92.2 degree for DFS and 56o for CFS. The increased bandwidth from 0.00428 rad/min to 0.0255 rad/min indicates faster response and improved noise rejection. The CFS has higher peak of 2.92 dB while DFS has no peak, again indicating better noise-attentuation.
2. The bandwidth increases from 0.00428 rad/min to 0.0255 rad/min for CFS to DFS.
1. The phase margin for CFS and DFS are 64 degree and 70 degree respectively. 2. The bandwidth for CFS and DFS are 0.0061 rad/min and 0.0078 rad/min respectively. Fig: Simulink block model for LacI system with external noise. For noise in replication of plasmid copy number, mean is 0, and variance is 10 for multiple feedback and 62.5 for open-loop systems respectively. For noise in production of plasmid copy number, mean is 0, and variance is 10 for multiple feedback and 18779 for open-loop systems respectively. The standard-deviation/mean value of the LacI is used to characterize the noise at the output. With external noise in the replication of copy number the normalised standard deviation is 0.0138 for multiple-feedback system and 0.0260 for open-loop system. With external noise in the production of LacI the normalised standard deviation is 5.1499e-04 for multiple-feedback system and 5.7262e-04 for open-loop system. With external noise in the production of LacI and the replication of copy number the normalised standard deviation is 0.0141 for multiple-feedback system and 0.0263 for open-loop system.
Interpretation 1. The increased phase margin for DFS indicates that DFS can take care of delays in production LacI directly and by virtue of production of multiple plasmid copies better than the CFS which has regulation only on the plasmid copy number. 2. This indicates faster expression of the protein LacI in the system with low noise. 3. The increased bandwidth nearly 6 times for DFS indicates a faster response and a better noise rejection over a wide range of frequencies indicating a far robust response as compared to CFS. 4. For system with higher IPTG concentrations, IPTG takes away LacI, and thus acting as an inducer. This makes the system resemble open loop system more as compared to IPTG at lower concentrations. 5. The phase margin of 70o and 64ofor DFS and CFS respectively indicates the difference in ability to take care of delays in the two systems has reduced. The bandwidth increase for DFS is not high as compared CFS, with IPTG concentration of 1000μM. Also, the bandwidth for DFS with1000μM IPTG is far lower as compared to the bandwidth of DFS with no IPTG. 6. In presence of external noise, the multiple-feedback system attenuates noise at the output better than open-loop system. A detailed review of all the Control analysis modelling attempted is available here. |