August/12 August 2009
From 2009.igem.org
(Difference between revisions)
Line 45: | Line 45: | ||
(sample No.) (concentration) | (sample No.) (concentration) | ||
- | 1-15N | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_I719005 I179005] (1-15N) 19.0 ng/uL |
- | 2-6P 27.0 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_K091101 K091101] (2-6P) 27.0 |
- | 1-18C | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_J23100 J23100] (1-18C) 21.5 |
- | 1-12H | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0070 C0070] (1-12H) 48.0 |
- | 1-23L | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_B0015 B0015] (1-23L) 23.7 |
- | + | 19.4 | |
- | 1-6I | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_R0040 R0040] (1-6I) 9.3 |
- | 1-20F 71.3 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_I15009 I15009] (1-20F) 71.3 |
- | 2-18F | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_K118013 K118013] (2-18F) 19.2 |
- | 1-14H 49.9 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0078 C0078] (1-14H) 49.9 |
- | 1-23J 21.3 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_I1466 I1466] (1-23J) 21.3 |
- | 1-12C 10.7 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_R0071 R0071] (1-12C) 10.7 |
- | 1-14F 32 | + | [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0077 C0077] (1-14F) 32 |
Revision as of 08:26, 21 August 2009
1.before Min prep
Checked the cell cultures transformed and plated out yesterday (8/10) for colony formation and made an approximate count of the number of colonies.
(plate number)-(location on plate) (no. of colonies) 1-14F 50< 1-14H 50< 1-23J 100~ 1-12C 100~ 2-18F 10
inoculate to iquid medium(5mL + Amp 5uL or Kan 25uL)
2.Transformation
to get new plasmid
each 4uL(DNA) , 1-2M , 1-12C : 2uL 1-2M Amp 2-8O 1-21F 2-21F 1-12A 2-8I 1-12C 2-24G 1-16G 1-18L Kan 2-11N '8/11sample 10uL RBS+2-8M(LasR) EpsE+Terminater (after 65℃ , 10min)
3.LB plate
LB(500uL)+Amp(2.5mL) *25 +Kan(0.5mL) *25
4.Min prep
Result of Nanodrop concentration check
(sample No.) (concentration) [http://partsregistry.org/wiki/index.php?title=Part:BBa_I719005 I179005] (1-15N) 19.0 ng/uL [http://partsregistry.org/wiki/index.php?title=Part:BBa_K091101 K091101] (2-6P) 27.0 [http://partsregistry.org/wiki/index.php?title=Part:BBa_J23100 J23100] (1-18C) 21.5 [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0070 C0070] (1-12H) 48.0 [http://partsregistry.org/wiki/index.php?title=Part:BBa_B0015 B0015] (1-23L) 23.7 19.4 [http://partsregistry.org/wiki/index.php?title=Part:BBa_R0040 R0040] (1-6I) 9.3 [http://partsregistry.org/wiki/index.php?title=Part:BBa_I15009 I15009] (1-20F) 71.3 [http://partsregistry.org/wiki/index.php?title=Part:BBa_K118013 K118013] (2-18F) 19.2 [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0078 C0078] (1-14H) 49.9 [http://partsregistry.org/wiki/index.php?title=Part:BBa_I1466 I1466] (1-23J) 21.3 [http://partsregistry.org/wiki/index.php?title=Part:BBa_R0071 R0071] (1-12C) 10.7 [http://partsregistry.org/wiki/index.php?title=Part:BBa_C0077 C0077] (1-14F) 32