Team:IIT Madras/Miscellaneous/Safety
From 2009.igem.org
(Difference between revisions)
(New page: {{:Team:IITM/main}} <html> <br><br><br><br><br><br> <head><style> body { background: #000; } #aContent { background-color:#fff; margin: 50px auto; padding: 10px 10px 60px 10px; wi...) |
|||
Line 42: | Line 42: | ||
<ol type="a"> | <ol type="a"> | ||
- | |||
<li>Access to the laboratory is limited or restricted at the discretion of the laboratory director when experiments or work with cultures and specimens are in progress.</li> | <li>Access to the laboratory is limited or restricted at the discretion of the laboratory director when experiments or work with cultures and specimens are in progress.</li> | ||
- | <li | + | <li>Persons wash their hands after they handle viable materials, after removing gloves, and before leaving the laboratory.</li> |
<li>Eating, drinking, smoking, handling contact lenses, applying cosmetics, and storing food for human use are not permitted in the work areas. Persons who wear contact lenses in laboratories should also wear goggles or a face shield. Food is stored outside the work area in cabinets or refrigerators designated and used for this purpose only.</li> | <li>Eating, drinking, smoking, handling contact lenses, applying cosmetics, and storing food for human use are not permitted in the work areas. Persons who wear contact lenses in laboratories should also wear goggles or a face shield. Food is stored outside the work area in cabinets or refrigerators designated and used for this purpose only.</li> | ||
<li>Mouth pipetting is prohibited; mechanical pipetting devices are to be used.</li> | <li>Mouth pipetting is prohibited; mechanical pipetting devices are to be used.</li> | ||
Line 52: | Line 51: | ||
<li>All cultures, stocks, and other regulated wastes are decontaminated before disposal by an approved decontamination method such as autoclaving. Materials to be decontaminated outside of the immediate laboratory are to be placed in a durable, leakproof container and closed for transport from the laboratory. Materials to be decontaminated outside of the immediate laboratory are packaged in accordance with applicable local, state, and federal regulations before removal from the facility.</li> | <li>All cultures, stocks, and other regulated wastes are decontaminated before disposal by an approved decontamination method such as autoclaving. Materials to be decontaminated outside of the immediate laboratory are to be placed in a durable, leakproof container and closed for transport from the laboratory. Materials to be decontaminated outside of the immediate laboratory are packaged in accordance with applicable local, state, and federal regulations before removal from the facility.</li> | ||
</ol> | </ol> | ||
+ | |||
+ | ==Safety Equipment (Primary Barriers)== | ||
+ | |||
+ | <ol type="a"> | ||
+ | <li>Special containment devices or equipment such as a biological safety cabinet is generally not required for manipulations of agents assigned to Biosafety Level 1.</li> | ||
+ | <li>It is recommended that laboratory coats, gowns, or uniforms be worn to prevent contamination or soiling of street clothes.</li> | ||
+ | <li>Gloves should be worn if the skin on the hands is broken or if a rash is present. Alternatives to powdered latex gloves should be available.</li> | ||
+ | <li>Protective eyewear should be worn for conduct of procedures in which splashes of microorganisms or other hazardous materials is anticipated.</li> | ||
+ | </ol> | ||
+ | |||
+ | ==Laboratory Facilities (Secondary Barriers)== | ||
+ | |||
+ | <ol type="a"> | ||
+ | <li>Laboratory has doors for access control.</li> | ||
+ | <li>Laboratory contains a sink for hand washing.</li> | ||
+ | <li>The laboratory is designed so that it can be easily cleaned.</li> | ||
+ | <li>Bench tops are impervious to water and are resistant to moderate heat and the organic solvents, acids, alkalis, and chemicals used to decontaminate the work surface and equipment.</li> | ||
+ | <li>Laboratory furniture is capable of supporting anticipated loading and uses. Spaces between benches, cabinets, and equipment are accessible for cleaning.</li> | ||
+ | <li>Laboratory has no windows that open to the exterior.</li> | ||
+ | </ol> | ||
+ | |||
{{:Team:IITM/footer}} | {{:Team:IITM/footer}} |
Revision as of 13:54, 20 October 2009
IIT Madras
The lab that was used by the IIT Madras iGEM 2009 team conformed to most of the standards for a biosafety 1 lab. Biosafety Level 1 is suitable for work involving well-characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment. Biosafety Level 1 is suitable for work involving well-characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment.
Standard Microbiological Practices
- Access to the laboratory is limited or restricted at the discretion of the laboratory director when experiments or work with cultures and specimens are in progress.
- Persons wash their hands after they handle viable materials, after removing gloves, and before leaving the laboratory.
- Eating, drinking, smoking, handling contact lenses, applying cosmetics, and storing food for human use are not permitted in the work areas. Persons who wear contact lenses in laboratories should also wear goggles or a face shield. Food is stored outside the work area in cabinets or refrigerators designated and used for this purpose only.
- Mouth pipetting is prohibited; mechanical pipetting devices are to be used.
- Policies for the safe handling of sharps are instituted.
- All procedures are performed carefully to minimize the creation of splashes or aerosols.
- Work surfaces are decontaminated at least once a day and after any spill of viable material.
- All cultures, stocks, and other regulated wastes are decontaminated before disposal by an approved decontamination method such as autoclaving. Materials to be decontaminated outside of the immediate laboratory are to be placed in a durable, leakproof container and closed for transport from the laboratory. Materials to be decontaminated outside of the immediate laboratory are packaged in accordance with applicable local, state, and federal regulations before removal from the facility.
Safety Equipment (Primary Barriers)
- Special containment devices or equipment such as a biological safety cabinet is generally not required for manipulations of agents assigned to Biosafety Level 1.
- It is recommended that laboratory coats, gowns, or uniforms be worn to prevent contamination or soiling of street clothes.
- Gloves should be worn if the skin on the hands is broken or if a rash is present. Alternatives to powdered latex gloves should be available.
- Protective eyewear should be worn for conduct of procedures in which splashes of microorganisms or other hazardous materials is anticipated.
Laboratory Facilities (Secondary Barriers)
- Laboratory has doors for access control.
- Laboratory contains a sink for hand washing.
- The laboratory is designed so that it can be easily cleaned.
- Bench tops are impervious to water and are resistant to moderate heat and the organic solvents, acids, alkalis, and chemicals used to decontaminate the work surface and equipment.
- Laboratory furniture is capable of supporting anticipated loading and uses. Spaces between benches, cabinets, and equipment are accessible for cleaning.
- Laboratory has no windows that open to the exterior.