Team:KULeuven/Modeling/Integrated Model

From 2009.igem.org


Tuning the controller

In this section we consider the problem of choosing the amount of proportional action in the feedback loop, in the following sections terminology and concepts of linear control theory are used. Of course It's obvious that the system will not behave in a linear way. But the concepts and design strategies of linear control theory can be translated to non-linear control theory.

One of the most useful ways of investigating the behaviour of closed loop system is the investigation of the open loop system. The open loop system is the system which one becomes if you 'remove' the differentiator.

Block model of the system with proportional controller

Stability

One can show that the proportional gain can not be infinitely large due to stability problems, since we lose phase margin if we increase the proportional gain. Oscillations will become larger as can be seen on the graph below. Eventually the oscillations become dominant and will destabilize the controlled system.

Stability of system, overshoot and oscillations increases with increasing gain of controller.

Tracking problem

We are mostly interested in the ability of the controlled system to follow a step input signal, for a linear system the steady state tracking error is:

Eqn7165.png

with T the total open loop gain. As we wish to eliminate the transfer of disturbances to the output of our system, we have to maximize the loop gain of the system. We have simulated this behaviour in the non linear model of our bacteria.

Tracking error on step input in function of amplitude and time

Disturbance rejection

Disturbance rejection is the ability to mask disturbances on the output, the transfer of disturbances d to the output y is given by

Eqn3.png

It now easily seen that we want to have a large enough enough open loop gain to reject disturbances on the output. We simulated a constant addition of alien vanillin to the extracellular medium.

Influence of disturbance on output, on t=6e5 we extract 2 molecules/s out of the extracellular medium

On the above figure it can be clearly seen that the influence of the perturbation on the output decreases with increasing open loop gain.