* Now that we obtained more Cre-Recombinase sample (see September 27th), we could proceed with Cre-Recombinase without ATG's biobrick construction.
 +
* We ran an agarose gel with Cre-Recombinase's PCR product, as well as pSB1A3's miniprep sample. We then purified the target bands with Purelink's Quick Gel Extrection Kit, according to the manufacturer's protocol ([https://2009.igem.org/Team:UNICAMP-Brazil/Protocols/Purification_of_DNA_fragments_from_agarose_gels Protocol 7]).
 +
 +
''Víctor''
====CeiB: Colony PCR ====
====CeiB: Colony PCR ====

Revision as of 18:59, 21 October 2009

Topo l2.gif topo_r_igem.gif
topo_r_b.gif
Back to Calendar

YeastGuard

Dephosphorylation - CIAP test

  • Only a few colonies were found this morning =(. Unfortunately the number of colonies wasn´t enough to compare and decide between CIAP and SAP. So we decided to use SAP to dephosphorylate our biofusion vector, considering that the protocol is much easier.

New biobricks

  • Today we performed 5' dephosphorylation of the biofusion vector with SAP (Protocol 9). We did the ligation reaction (Protocol 11) with the 5' dephosphorylated vector and the three digested (XbaI and SpeI) new parts (pJen1, pDLD and Lysozyme).

  • We transformed the thermocompetent E. coli (Protocol 3) with the ligations and plated in LB+Amp media.


Raíssa and Taís


Customizing the PCR

  • Gradient PCR of the Jen1 (ORF) using the melting temperatures: 53ºC, 55ºC and 57ºC. How you can see in the gel, this amplification wasn’t so good. Then the strategy will be: join the three products obtained by this gradient PCR and make a electrophoresis to purify the band corresponding to the Jen1 (ORF) size and ,then, make a new PCR.

  • To get a optimal PCR that can amplify the …… using the primers VF and VR we did a gradient PCR. The temperatures tested were the same of the Jen1 (ORF) PCR.

  • The electrophoresis didn’t show big differences into the three melting temperatures used and the bands pattern correspond to the size of ………


Gradiente.JPG

Wesley and Gleidson

ColiGuard

Cre-Recombinase's and pSB1A3's purification

  • Now that we obtained more Cre-Recombinase sample (see September 27th), we could proceed with Cre-Recombinase without ATG's biobrick construction.
  • We ran an agarose gel with Cre-Recombinase's PCR product, as well as pSB1A3's miniprep sample. We then purified the target bands with Purelink's Quick Gel Extrection Kit, according to the manufacturer's protocol (Protocol 7).

Víctor

CeiB: Colony PCR

  • <p We got transforming cells apparently. We made colony PCR with VF and VR primer in order to prove the transformation. The CeaB transformation was wrong, because of don’t show the right size band. We tried one more time transformation. Otherwise the CeiB transformation showed possible correct band size (~400), then to confirm, we are going to make miniprep tomorrow and PCR again.</p>


29 set.jpg

Luige

Miniprep Results

  • We ran an agarose gel with the minipreps samples (proccedure performed yesterday).

Miniprep2809 17H 17J 24M.jpg

Miniprep2809 12O.jpg


  • According to both pictures, we sucessfully recovered all biobricks! :)


Marcelo