Team:Calgary/Lab/Reporter
From 2009.igem.org
(Difference between revisions)
(11 intermediate revisions not shown) | |||
Line 85: | Line 85: | ||
<br> | <br> | ||
The reporter circuit is used to test whether the signalling circuit is functional. It has been designed and constructed with the qrr4 promoter followed by GFP. In the absence of AI-2, the end product of the signalling cascade is phospho-LuxO, which will bind to the qrr4 promoter and therefore produce fluorescence. In the presence of AI-2 however, the end product of the signalling cascade is LuxO, which will not bind to the qrr4 promoter, and therefore the colonies will not glow. | The reporter circuit is used to test whether the signalling circuit is functional. It has been designed and constructed with the qrr4 promoter followed by GFP. In the absence of AI-2, the end product of the signalling cascade is phospho-LuxO, which will bind to the qrr4 promoter and therefore produce fluorescence. In the presence of AI-2 however, the end product of the signalling cascade is LuxO, which will not bind to the qrr4 promoter, and therefore the colonies will not glow. | ||
+ | <br> | ||
<br> | <br> | ||
<br> | <br> | ||
Line 93: | Line 94: | ||
<br> | <br> | ||
</html> | </html> | ||
- | [[Image: | + | [[Image:Fluorescent_Reading_Calgary2.png|700px]] |
<html> | <html> | ||
</center> | </center> | ||
Line 114: | Line 115: | ||
<br>9. Measure OD600 again. | <br>9. Measure OD600 again. | ||
<br>10. Once OD600 are matching for all samples, serial dilute them (1 in 10, 1 in 100). To serial dilute, aliquot 100uL of original culture into a new tube containing 900uL of corresponding LB broth (1 in 10). To make 1 in 100, aliquot 100uL of 1 in 10 dilution into a new tube containing 900uL of corresponding LB broth (1 in 100). | <br>10. Once OD600 are matching for all samples, serial dilute them (1 in 10, 1 in 100). To serial dilute, aliquot 100uL of original culture into a new tube containing 900uL of corresponding LB broth (1 in 10). To make 1 in 100, aliquot 100uL of 1 in 10 dilution into a new tube containing 900uL of corresponding LB broth (1 in 100). | ||
- | <br>11. Go back to wizard, change the reading parameters to the following settings*: | + | <br>11. Go back to wizard, change the reading parameters to the following settings<b>*</b>: |
<br>Reader: Fluorescence | <br>Reader: Fluorescence | ||
<br>Reading type: Endpoint | <br>Reading type: Endpoint | ||
Line 125: | Line 126: | ||
<br>13. Again, go to wizard, change the layout of the cells. | <br>13. Again, go to wizard, change the layout of the cells. | ||
<br>14. Read. | <br>14. Read. | ||
- | <br>*GFP reading protocol was obtained from Minenesota State University<br> http://www.mnstate.edu/provost/GFPPlateReaderAssayProtocol.pdf | + | <br><b>*GFP reading protocol was obtained from Minenesota State University<br> http://www.mnstate.edu/provost/GFPPlateReaderAssayProtocol.pdf, date accessed: August 10th, 2009</b> |
<br> | <br> | ||
+ | </html> | ||
+ | |||
+ | {|border=1 width="90%" align="center" | ||
+ | |- | ||
+ | !width="20%" style="background:#FFFFFF"|Parameter | ||
+ | !width="80%" style="background:#FFFFFF"|Value and Description | ||
+ | |-align="center" | ||
+ | |Optimal Temperature | ||
+ | |37°C | ||
+ | |-align="center" | ||
+ | |Required Bacteria | ||
+ | |Strain of ''E. coli'', such as TOP10 and KT1144 | ||
+ | |} | ||
+ | <html> | ||
<br> | <br> | ||
For an in depth look into the construction and testing of reporter circuit (complete with results) please read the paper below. | For an in depth look into the construction and testing of reporter circuit (complete with results) please read the paper below. |
Latest revision as of 03:37, 22 October 2009
UNIVERSITY OF CALGARY