Team:Aberdeen Scotland/parameters/invest 5

From 2009.igem.org

(Difference between revisions)
Line 4: Line 4:
= The Amended Model =  
= The Amended Model =  
-
The model we now look at is the final step in our progression.  We take a system with constitutive production of LuxR and have LuxI on a feedback loop using a weak Luxbox.
+
The model we now look at is the final step in our progression.  We take a system with constitutive production of LuxR (on the J23105, 0.0104 POPS) and have LuxI on a feedback loop using a weak Luxbox. (0.002 max POPS, 0.00015 min POPS)
[[Image:Qs invest 4.jpg|center|300px]]
[[Image:Qs invest 4.jpg|center|300px]]
Line 20: Line 20:
So our system is also very robust for different values of K<sub>P</sub>.
So our system is also very robust for different values of K<sub>P</sub>.
-
 
-
The next three plots show what would happen if K<sub>P</sub> was equal to 500 molecules per cell
 
-
 
-
[[Image:Amended Model 5.jpg|center|700px]]
 
-
[[Image:Amended Model 6.jpg|center|700px]]
 
-
[[Image:Amended Model 7.jpg|center|700px]]
 
{{:Team:Aberdeen_Scotland/break}}
{{:Team:Aberdeen_Scotland/break}}

Revision as of 11:02, 12 August 2009

University of Aberdeen iGEM 2009

The Amended Model

The model we now look at is the final step in our progression. We take a system with constitutive production of LuxR (on the J23105, 0.0104 POPS) and have LuxI on a feedback loop using a weak Luxbox. (0.002 max POPS, 0.00015 min POPS)

Qs invest 4.jpg

This allows us to use the literature value of KP while still getting good results. We see in the next few plots that the values of KCI and KTetR are very robust in this model:

Amended Model 1.jpg
Amended Model 2.jpg

We know from the literature that KCI is expected to be greater than KTetR. This means that we can assume that in a worst case scenario KCI might be equal to KTetR. We use this worst case assumption now to check the relationship between KCI (= KtetR) VS. KP. This is what we find:

Amended Model 3.jpg
Amended Model 4.jpg

So our system is also very robust for different values of KP.

The required levels of HSL outside and IPTG outside

The only area left to explore is how the levels of the input molecules affect the output. We do this here in the same manner as was done for previous versions of the system.


Amended Model 8.jpg
Amended Model 9.jpg
Amended Model 10.jpg

Conclusion

Here is how our system functions with the parameters we believe to be correct:

Amended Model 11.jpg

We can conclude that this system is very robust for K CI, KTetR, KlacI and KP. It can be activated by lower levels of HSL and IPGT than its predecessors and consistently produces large quantities of the glue molecule, molecule X. We have also shown that it is capable of latching behaviour for quorum sensing, given the right promoter strengths on the luxI feedback lux box.