Team:Aberdeen Scotland/parameters/invest 5
From 2009.igem.org
Nick Smart (Talk | contribs) |
Nick Smart (Talk | contribs) (→Conclusion) |
||
Line 37: | Line 37: | ||
[[Image:Amended Model 11.jpg|center|700px]] | [[Image:Amended Model 11.jpg|center|700px]] | ||
+ | |||
+ | [[Image:Amended Model 13.jpg|center|700px]] | ||
We can conclude that this system is very robust for K <sub>CI</sub>, K<sub>TetR</sub>, K<sub>lacI</sub> and K<sub>P</sub>. It can be activated by lower levels of HSL and IPGT than its predecessors and consistently produces large quantities of the glue molecule, molecule X. We have also shown that it is capable of latching behaviour for quorum sensing, given the right promoter strengths on the luxI feedback lux box. | We can conclude that this system is very robust for K <sub>CI</sub>, K<sub>TetR</sub>, K<sub>lacI</sub> and K<sub>P</sub>. It can be activated by lower levels of HSL and IPGT than its predecessors and consistently produces large quantities of the glue molecule, molecule X. We have also shown that it is capable of latching behaviour for quorum sensing, given the right promoter strengths on the luxI feedback lux box. |
Revision as of 12:35, 12 August 2009
University of Aberdeen - Pico Plumber
The Amended Model
The model we now look at is the final step in our progression. We take a system with constitutive production of LuxR (on the J23105, 0.0104 POPS) and have LuxI on a feedback loop using a weak Luxbox. (0.002 max POPS, 0.00015 min POPS)
This allows us to use the literature value of KP while still getting good results. We see in the next few plots that the values of KCI and KTetR are very robust in this model:
We know from the literature that KCI is expected to be greater than KTetR. This means that we can assume that in a worst case scenario KCI might be equal to KTetR. We use this worst case assumption now to check the relationship between KCI (= KtetR) VS. KP. This is what we find:
So our system is also very robust for different values of KP.
The required levels of HSL outside and IPTG outside
The only area left to explore is how the levels of the input molecules affect the output. We do this here in the same manner as was done for previous versions of the system.
Conclusion
Here is how our system functions with the parameters we believe to be correct:
We can conclude that this system is very robust for K CI, KTetR, KlacI and KP. It can be activated by lower levels of HSL and IPGT than its predecessors and consistently produces large quantities of the glue molecule, molecule X. We have also shown that it is capable of latching behaviour for quorum sensing, given the right promoter strengths on the luxI feedback lux box.