- | <partinfo>BBa_I746902</partinfo>: This part was not present in 2009 DNA Distribution and no quality control had been performed. The UNIPV-Pavia requested this part to iGEM Headquarters, sequenced it and found that sequence was correct ( | + | <partinfo>BBa_I746902</partinfo>: This part was not present in 2009 DNA Distribution and no quality control had been performed. The UNIPV-Pavia requested this part to iGEM Headquarters, sequenced it and found that the covered part of the sequence was correct (almost all the sequence was covered). |
<div align="right"> | <div align="right"> | ||
Line 113: | Line 113: | ||
=====BBa_K112808===== | =====BBa_K112808===== | ||
- | <partinfo>BBa_K112808</partinfo>: After the alignment of this BioBrick sequence from 2009 DNA Distribution with the theoretical sequence, many difformities have been reported (sequencing results have been taken from iGEM QC): i) the alignment showed several gaps in the scars; ii) there is a silent point mutation in holin gene; iii) the transcriptional terminator at the end of the sequence is actually K112710, not B0010. | + | <partinfo>BBa_K112808</partinfo>: After the alignment of this BioBrick sequence from 2009 DNA Distribution with the theoretical sequence, many difformities have been reported (sequencing results have been taken from iGEM QC): i) the alignment showed several gaps in the scars; ii) there is a silent point mutation in holin gene; iii) the transcriptional terminator at the end of the sequence is actually K112710, not B0010. However, the part should work properly because the regulatory parts and the amino acid sequence of the genes are correct. This has also been confirmed by functional tests. |
- | + | ||
- | However, the part should work properly because the regulatory parts and the amino acid sequence of the genes are correct. This has also been confirmed by functional tests | + | |
<div align="right"> | <div align="right"> |
Latest revision as of 16:14, 21 October 2009
|
Existing parts: debug |
|
Re-built existing parts (BBa_our part code/BBa_existing part code) Existing parts from the Registry Existing parts sequence debugging:
During this summer, we sequenced and carefully analyzed sequencing results of some existing BioBrick parts. Some of them were not present in DNA Distribution, so they have been sent us by iGEM Headquarters. BBa_T9002
BBa_K131009
BBa_K131010
BBa_K116001
BBa_K116002
BBa_P0412
BBa_K112405
BBa_K101017
BBa_I746902
BBa_I746903
BBa_K112808
BBa_F2620
All these comments are also reported in the Experience pages of the relative BioBrick parts in the Registry web site.
|