Team:Calgary/Lab/Protocol
From 2009.igem.org
Line 85: | Line 85: | ||
</div> | </div> | ||
<div class="desc"> | <div class="desc"> | ||
+ | </html> | ||
The following are the protocols that are used in the lab this year. Some modifications may have occured during this summer. If there are any changes, those changes can be found in the notebook. | The following are the protocols that are used in the lab this year. Some modifications may have occured during this summer. If there are any changes, those changes can be found in the notebook. | ||
</div> | </div> |
Revision as of 22:49, 28 July 2009
LAB INDEX
Overview
Updates -LuxPQ -LuxOU -LuxCDABE -pqrr4 -LuxOD47A -LuxOD47E -DUHN DUHN DUHN Protocol & Safety |
Lab Protocols
The following are the protocols that are used in the lab this year. Some modifications may have occured during this summer. If there are any changes, those changes can be found in the notebook.
</div>
For this protocol we used a couple of controls
Biobrick parts are shipped from the registry in a dehydrated from. As such they must be rehydrated before they can be used.
Thermocycler Conditions
Conditions were varied as needed. For example in cases of longer products all 1 minute times were increased to 1.5 or even 3 minutes
Determine the order of the two parts you will be putting together; the one in front will be referred to as the insert, while the one behind will be referred to as the vector. Both the vector and the insert need to have their own separate tube, at least in the beginning. Restriction Digest Protocol In the Insert Tube...
In the vector Tube...
Put both tubes into the 37°C water bath for one hour. After, place them into the 65°C heating block for 10 minutes. This deactivates any enzymes in the tube (which is ok, because by now they’ve done all they need to). Take the insert out, and put it in a -20°C freezer. Antarctic Phosphatase Protocol To the vector tube, add 5 μL of 10x Antarctic Phosphatase Buffer, 4 μL of water, and 1 μL of Antarctic Phosphatase. We do this to prevent the vector from closing up again without any insert. Put the tube into the 37°C water bath for 30 mins. After, place it in the 65°C heating block for 10 minutes. Ligation Protocol Take the insert out of the freezer, and add 5 μL of insert and 5 μL of vector to a new tube. Label the rest of each tube as Unligated, put the date on the tube, and stick it in the -20°C freezer incase your ligation/transformation doesn’t work. To the single tube of 10 μL mix, add 10 μL of 2x Quick Ligase Buffer, and 1 μL of Quick Ligase. Let this sit at room temperature for 5 minutes. You are now done. If you are going to transform this construction product, add all 21μL to a tube of whichever competent bacteria you're using.
Adapted from Butanerds Protocols from the University of Alberta iGEM Protocols pdf What you will need
Protocol
Adapted from Butanerds Protocols from the University of Alberta iGEM Protocols pdf What you will need
Protocol
Adapted from Butanerds Protocols from the University of Alberta iGEM Protocols pdf What you will need
Protocol
This protocol is also described as a part of our Construction Technique. Start by selecting the order of the two parts you will be putting together; the one in front will be referred to as the insert, while the one behind will be referred to as the vector. Both the vector and the insert need to have their own separate tube, at least in the beginning. This is important because it allows for clean addition new parts to a the circut In the Insert Tube...
In the vector Tube...
Put both tubes into the 37°C water bath for one hour. After, place them into the 65°C heating block for 10 minutes. This destroys any enzymes in the tube (which is ok, because by now they’ve done all they need to). Take the insert out, and put it in a -20°C freezer.
This protocol is also described as a part of our Construction Technique. Start by selecting the order of the two parts you will be putting together; the one in front will be referred to as the insert, while the one behind will be referred to as the vector. Both the vector and the insert need to have their own separate tube, at least in the beginning. This is important because it allows for clean addition new parts to a the circut
Retrieved from "http://2009.igem.org/Team:Calgary/Lab/Protocol"
|