Protocol: Used Sigma GenElute Plasmid Miniprep Kit (Sigma), lot # 048k6062, used as according to the manufacturers instructions.
Results: Used Nanodrop 1000 Spectrophotometer read at 260 wavelength to determine DNA concentrations
Plasmid 260/280 260/230 Concentration [ng/μL]
LuxOD47E Topo C1 1.88 2.21 409.5
LuxOD47E Topo C2 1.86 2.18 551.4
LuxOD47E BBK C1 2.04 5.01 551.4
LuxOD47E BBK C2 1.77 1.39 92.9