Testing
OD calibration 17th Sep
Protocol considerations
- Cells were grown overnight in 10ml of M9 media
- The cells were allowed to grow until a high OD (very cloudy) and retrieved in the early afternoon
- The OD was measured using the multiplate reader.
- As the OD was only around 1.5, the cells were centrifuged and resuspended in less media to form an OD of 3
- OD of around 0.5 to 3.0 was made up, and subsequently diluted up to 10-6 to 10-8
- Plated on strep plates and dried until the end of the day
- Placed into 37 degrees incubator (non-shaking) overnight
Results
The plates had too many colonies to count.
Conclusions
- The plates were all too confluent, even at 10-8 dilution.
- Unable to count colonies and draw any colonies
- Need to repeat experiment
Suggestions/Improvements
- Was not done on ice, so cell growth still occurred during dilutions
- Too many colonies to count when plated 100uL
- Use ice
- Increase dilutions