Team:NTU-Singapore/Project/System

From 2009.igem.org

Revision as of 05:19, 19 October 2009 by Iandravid (Talk | contribs)

Our Solution



In the previous section, we identified some characteristic conditions present at atherosclerotic sites.

Now we will start formulating a solution in the framework of a system. The idea here is to utilize the engineering approach to solve our problem. The engineering approach to solving problems is a logical and structured way to custom design a unique solution.

This approach suits the purposes of iGEM and Registry of Biological Parts very well, because the aim of synthetic biology is to systemize biology. This will empower us to engineer biological solutions to problems.

Parts, devices & systems

NTUsysdevpar.jpg

The first step to systemizing would be to recognize that any system is made up of devices, which in turn consist of parts. This is known as an abstraction hierarchy.

In the context of iGEM, parts would be functional gene sequences, devices would be individual Biobricks, and the resulting system is a coherent & working biological machine.


The purpose of an abstraction hierarchy is simple. By abstracting a synthetic genome into these layers, we can start to blackbox and isolate the gene sequences or the functions that we are interested in. This means, at every level in the hierarchy, one need only concentrate on the workings of that layer and nothing else.

For example, someone making a circuit does not need to know the inner workings of a battery or the switch. He/she can just expect it to work in a predictable way. Similarly, someone working on a biological device does not have to worry about the details of the parts being used.


This modularization is made possible with Biobricks, bringing us one step closer to Tom Knight's dream of plug-and-play biology. In this way, synthetic biology can be advanced in the same reductionistic way that has best suited the study of biology.


The Engineering Approach

Now that we understand what systemizing means, let's look at how we can use systems/sub-systems (devices) in the engineering process. Below is the typical flow of the engineering process. We have, in order of sequence:


NTUenggapp.jpg


  • Problem Identification : In our case, we recognize atherosclerosis as our problem.
  • System Specifications : We will identify the parameters that can be manipulated or need to be controlled.
  • System Design : We will propose and design a system to solve the problem.
    • Device Design : Design devices (and parts) that, when combined, fulfill the specifications of our system.
    • Modelling : We simultaneously model both the system & its devices to identify bottlenecks.
  • Prototyping : We will make a proof-of-concept that highlights the potential engineering difficulties.
  • System Construction : If the prototype is successful, we can actually construct the intended system.
  • Testing & Characterisation : We verify the functionality of our system & compare to the modelling.


So let's start to analyze our problem, atherosclerotic plaque, and layout our proposed solution according to these steps.


System Specifications

We have already identified the problem and collated its characteristics. So the logical next step is to define the system parameters or system specifications. Each of these parameters are chosen from the analysis of characteristics of physiological plaque inflammation.

In general, our defined parameters will outline what exactly our system is going to do to achieve the goal of imaging and breaking down plaque in vivo.


From our research, we propose the following as the system parameters:

  • Our system must sense changes in blood [NO]. If it falls below a certain level, then system is triggered to switch on.
    • Since our system will also be selective to damaged arterial walls thanks to catch bonds, we can be fairly certain of the specificity of our system to atherosclerotic plaque sites.


  • The system must release enzymes to breakdown the cholesteryl esters in plaque.


  • The system must additionally release a reporter protein that allows for for in vivo visualisation.
    • This is to enable easy and early diagnosis.


  • The system must re-generate [NO] at site.
    • Not only does this dilate the vessel, it also serves as feedback to the system to shut down.


Now that we have defined our system parameters, we can decide on the parts and devices we can use to build our system from scratch.


Ideal System Design

We can generally agree at this stage, that our ideal system must be based in a mammalian blood cell; the function and requirements of the system specifications demand such an approach. Ideally a T-helper cell would be used. The advantage of using a T-helper cell is that expression/exhibition of PSGL-1 at the surface becomes trivial.


The team also decided that each of the four specifications should be satisfied by four separate constructs in a genetic activation/repression circuit. These would be the devices that make up our system.

We have defined the four devices as the following:

  • Sense device : To detect changes in physiological blood [NO].
  • Degradation device : To secrete cholesterol esterase to break down the lipid core.
  • Imaging device : To identify and monitor plaque sites in vivo.
  • Dilation device : To re-generate [NO] & feedback to shutdown.


NTUsysdev.gif


Here's how we see our system working.

  1. Our system is injected into the bloodstream anywhere in the body.
  2. The Sense device actively samples the blood [NO].
    1. In healthy [NO] conditions, our Sense device actively inhibits the functioning of the other devices.
    2. Once blood [NO] falls to critical levels, our Sense device is de-activated, and the other devices are not inhibited anymore.
    3. We also expect that our system would bind selectively to the damaged endothelium at the plaque site.
  3. The Degradation device releases cholesterol esterase into the plaque.
  4. The Imaging device releases a reporter protein that can be imaged in vivo.
    1. We have identified a protein expressly for this purpose. It will be detailed in the next section.
  5. After a programmed delay mechanism, the Dilation device will start to release an enzyme to re-generate [NO] at the plaque site.


Each of these devices will be the final construct-Biobricks that we intend to achieve. We have to now populate these devices with the parts to make the device work the way we want them to.


Unfortunately, our laboratories are not sufficiently equipped to deal with mammalian cells. We also felt that the iGEM time period is not sufficient to make a mammalian biological system. Due to these time and equipment constraints, we will not detail the design of the ideal system, since we will not be able to build it anyway.

Instead, we will focus on designing a full-blown prototype system as a proof-of-concept, using E.Coli as our model organism.


Prototype System Design

Recall the construct layout for the ideal system above. Our prototype will utilize a similar layout. We will now detail the parts we have identified for our devices.


Sense Device


NTUsensedevice.png


  • Arguably the most important gene sequence, we have decided to use the NO-sensitive promoter region of the NorV/W gene sequence endogeneous in E.Coli.
    • This NO-sensitive promoter (we will refer to it as pNO henceforth) will be the active NO-sensor for our system.
      • pNO is ON in high [NO] conditions & OFF in low [NO] conditions.


  • The pNO will be placed upstream of a TetR gene sequence.
    • The rationale here is that in healthy [NO] condition, pNO is activated and will facilitate expression of TetR. TetR is used to repress the other devices. In low [NO] conditions, pNO will be deactivated and the transcription of TetR gene sequence will stop. Hence repression of other devices will stop.


Degradation Device


NTUdegradevice.png


  • As mentioned above, the pTet promoter will serve as the controller for this device.
    • In high [TetR] conditions, implying high [NO] conditions, Degradation device is OFF. In low [TetR], implying low [NO] conditions, this device will be ON.


  • LuxI gene sequence is inserted to regulate the Dilation device.
    • We will explain this in detail later in the Dilation device.


  • CHE gene sequence will express Cholesterol Esterase enzyme.
    • This enzyme will breakdown the cholesteryl esters in plaque.


Imaging Device


NTUimagingdevice.png


  • Again, pTet regulation will control the activation/repression of this device.
    • System is only ON at high [NO] and OFF at low [NO].


  • The Heme-Oxygenase 1 gene sequence (HO-1) and Infrared Protein gene sequence (IFP) are to be considered coupled.
    • HO-1 expression will facilitate the conversion of heme to biliverdin.
    • IFP, a protein discovered by Tsien lab, requires bilverdin to be stable and fluoresce in the infra-red spectrum.


Dilation device


NTUdilationdevice.png


The Dilation device is special because it features a "delay" mechanism endemic to E.Coli. This delay mechanism will be replaced with a mammalian counterpart if designing the actual mammalian biological system.

  • The Dilation device features constitutive transcription of LuxR gene sequence.
    • [LuxR] will repress the activation of pLuxR further downstream.


The following is our E.Coli delay mechanism.

  • pLuxR is activated when LuxR is removed by selective binding to AHL.
    • This is where the LuxI from the Degradation device comes in.
      • LuxI converts SAM protein to AHL. AHL binds to LuxR. We expect this series of binding comes with a time lag.
    • Recall that Degradation device is only ON at high [NO] conditions.
      • Hence pLuxR is only activated at high [NO] conditions, and only after a lag period.


  • Activated pLuxR allows for transcription of Nitric Oxide Synthase [NOS].
  • NOS will then regenerate [NO] at plaque site.


System Construction

So now we have designed a coherent system complete with devices with specific objectives and parts with well-defined gene sequences.

At this stage, we are ready to begin our labwork. To clearly define the scope of our Wet Lab, we have come up with a research proposal. Please proceed here to read our Research Proposal.


Literature / References

Please proceed here to view our full list of references.



NTU@iGEMcc 2009. Some rights reserved.