Team:Cambridge/Project/VI03

From 2009.igem.org

(Difference between revisions)
(Characterisation)
(Proof of pigment production)
Line 27: Line 27:
The Vio operon is currently on a very low copy number plasmid; moving it onto a higher copy number plasmid may accelerate pigment production.
The Vio operon is currently on a very low copy number plasmid; moving it onto a higher copy number plasmid may accelerate pigment production.
-
[[Image:Cam09_vio.jpg|400px]][[Image:Cam09_vio1.jpg|400px]]
+
[[Image:Cam09_vio.jpg|300px]][[Image:Cam09_vio1.jpg|300px]]
 +
 
 +
Left: Violacein growth on agar plate (overnight). Right: Single colonies.
=== Characterisation of colour output ===
=== Characterisation of colour output ===

Revision as of 23:03, 21 October 2009


Violacein Pigments


Characterisation

Proof of pigment production

Successful Pigment Production

We transformed Top10 with pPSX-Vio+. After three colour eventually appeared, as shown below. Interestingly, the pigment appears to remain within the bacteria, with little or no bleeding into the media. We took the violacein pigment bacteria (right plate in photo) out of the fridge to find that the purple colour had started to develop. They were therefore left at room temperature overnight. The colour appears to be within the bacteria, with little or no bleeding into the media. The control plate (left plate) is the untransformed TOP10 E. coli.

Cambridge Violacein Pigment.jpg

Left: control plate - untransformed TOP10 E. coli, Right: Top10 transformed with pPSX-Vio+.

Pigment production efficienty

The Vio operon is currently on a very low copy number plasmid; moving it onto a higher copy number plasmid may accelerate pigment production.

Cam09 vio.jpgCam09 vio1.jpg

Left: Violacein growth on agar plate (overnight). Right: Single colonies.

Characterisation of colour output

We characterised the violacein pigment by carrying out the acetone extraction protocol used for carotene. The results were normalised for OD and then plotted as a graph of absorption units against wavelength:

Vio wavelength graph.JPG

We also looked at absorbance at 584nm (the maximum absorbance for violacein):

Vio absorbance.JPG


Cambridge Sponsor Logo1.pngCambridge Sponsor Logo2.pngCambridge Sponsor Logo3.pngCambridge Sponsor Logo4.pngCambridge Sponsor Logo5.pngCambridge Sponsor Logo8.pngCambridge Sponsor Logo6.pngCambridge Sponsor Logo7.pngCambridge Sponsor Logo9.pngCambridge Sponsor Logo10.pngCambridge Sponsor Logo11.pngCambridge Sponsor Logo12.pngCambridge Sponsor Logo14.pngCambridge Sponsor Logo13.pngCambridge Sponsor Logo15.pngCambridge Sponsor Logo16.pngCambridge Sponsor Logo17.pngCambridge Sponsor Logo18.pngCambridge Sponsor Logo19.pngBmglab.jpg