Team:Heidelberg/Notebook measure/NotebookMi
From 2009.igem.org
(Difference between revisions)
(→Contents) |
|||
Line 87: | Line 87: | ||
[[image:HD09_Hannah_HeLa_GFP.JPG|350px| center|thumb|'''Figure 1: HeLa cells transfected with CMV in front of GFP.''' Image taken with 40x magification.]] | [[image:HD09_Hannah_HeLa_GFP.JPG|350px| center|thumb|'''Figure 1: HeLa cells transfected with CMV in front of GFP.''' Image taken with 40x magification.]] | ||
- | == 9- | + | == 9-02-2009 == |
* Microscopy of cells transfected with cmv, jet, cmv-jet with GFP and an mCherry control | * Microscopy of cells transfected with cmv, jet, cmv-jet with GFP and an mCherry control | ||
* Measurement of exposure time versus average grey value to check whether there is a linear correlation between the two. This measurement was performed using a fluorescent slide that has constant fluorescence and doesn't bleach. The correlation factor was calculated to be 0.9998. Therefore we can calculate the grey values of samples with different exposure times. | * Measurement of exposure time versus average grey value to check whether there is a linear correlation between the two. This measurement was performed using a fluorescent slide that has constant fluorescence and doesn't bleach. The correlation factor was calculated to be 0.9998. Therefore we can calculate the grey values of samples with different exposure times. | ||
Line 93: | Line 93: | ||
[[image:HD09_microscopy_exposuretime.PNG|center|350px|thumb|'''Figure 2: Graph of exposure time versus average grey values''' The correlation factor is indicated on the diagram.]] | [[image:HD09_microscopy_exposuretime.PNG|center|350px|thumb|'''Figure 2: Graph of exposure time versus average grey values''' The correlation factor is indicated on the diagram.]] | ||
- | == 9- | + | == 9-05-2009 == |
* Test the bleaching effect of our GFP by exciting it over 10 minutes and taking images every 10 seconds. The images were evaluated for their fluorescence intensities using the imaging software NTS Elements-3.1. The data is shown in the diagram below. | * Test the bleaching effect of our GFP by exciting it over 10 minutes and taking images every 10 seconds. The images were evaluated for their fluorescence intensities using the imaging software NTS Elements-3.1. The data is shown in the diagram below. | ||
[[image:HD09_microscopy_bleachingGFP.PNG|center|350px|thumb|'''Figure 3: Bleaching of GFP.''' This diagram shows the percent fluorescence intensity versus time of our GFP. The initial fluorescence intensity was set to 100% The correlation factor is indicated on the diagram.]] | [[image:HD09_microscopy_bleachingGFP.PNG|center|350px|thumb|'''Figure 3: Bleaching of GFP.''' This diagram shows the percent fluorescence intensity versus time of our GFP. The initial fluorescence intensity was set to 100% The correlation factor is indicated on the diagram.]] | ||
- | == 9- | + | == 9-06-2009 == |
* Fixing cells with 4% formaldehyde for standard promoters JeT, JeT-CMV and CMV in HeLa. HeLa cells were cotransected with a plasmid containing JeT in front of mCherry as a reference in a 2:1 GFP: mCherry ratio. | * Fixing cells with 4% formaldehyde for standard promoters JeT, JeT-CMV and CMV in HeLa. HeLa cells were cotransected with a plasmid containing JeT in front of mCherry as a reference in a 2:1 GFP: mCherry ratio. | ||
- | == 9- | + | == 9-07-2009 == |
* Imaging of HeLa with three standard promoters, example image shown below. | * Imaging of HeLa with three standard promoters, example image shown below. | ||
* Image analysis using ImageJ. | * Image analysis using ImageJ. | ||
Line 110: | Line 110: | ||
[[Image:HD09 microscopy HeLastand.PNG|center|350px|thumb|'''Figure 5: Graph of exposure time versus average grey values''' Mean grey values were obtained using ImageJ analysis of 20x widefield microscopy images. The promoter strength is given relative to our standard promoter JeT. Mean grey values were adjusted according to their exposure time.]] | [[Image:HD09 microscopy HeLastand.PNG|center|350px|thumb|'''Figure 5: Graph of exposure time versus average grey values''' Mean grey values were obtained using ImageJ analysis of 20x widefield microscopy images. The promoter strength is given relative to our standard promoter JeT. Mean grey values were adjusted according to their exposure time.]] | ||
- | == 9- | + | == 9-09-2009 == |
* Fix MCF7 cells for standard measurement. | * Fix MCF7 cells for standard measurement. | ||