Team:BIOTEC Dresden

From 2009.igem.org

(Difference between revisions)
(Prototype team page)
 
(42 intermediate revisions not shown)
Line 1: Line 1:
-
<!-- *** What falls between these lines is the Alert Box!  You can remove it from your pages once you have read and understood the alert *** -->
+
{{:Team:BIOTEC_Dresden/NewTemplateMain}}
 +
{{:Team:BIOTEC_Dresden/NewTemplateNoBar}}
-
<html>
 
-
<div id="box" style="width: 700px; margin-left: 137px; padding: 5px; border: 3px solid #000; background-color: #fe2b33;">
 
-
<div id="template" style="text-align: center; font-weight: bold; font-size: large; color: #f6f6f6; padding: 5px;">
 
-
This is a template page. READ THESE INSTRUCTIONS.
 
-
</div>
 
-
<div id="instructions" style="text-align: center; font-weight: normal; font-size: small; color: #f6f6f6; padding: 5px;">
 
-
You are provided with this team page template with which to start the iGEM season.  You may choose to personalize it to fit your team but keep the same "look." Or you may choose to take your team wiki to a different level and design your own wiki.  You can find some examples <a href="https://2009.igem.org/Help:Template/Examples">HERE</a>.
 
-
</div>
 
-
<div id="warning" style="text-align: center; font-weight: bold; font-size: small; color: #f6f6f6; padding: 5px;">
 
-
You <strong>MUST</strong> have a team description page, a project abstract, a complete project description, and a lab notebook.  PLEASE keep all of your pages within your teams namespace. 
 
-
</div>
 
-
</div>
 
-
</html>
 
-
<!-- *** End of the alert box *** -->
 
 +
===<center>Factory-on-a-chip: Temporal and spatial control of protein synthesis </center>===
 +
 +
===<center>by ''in vitro'' recombination inside picoliter reactors</center>===
 +
 +
 +
 +
<br>
 +
<br>
 +
 +
Organizing matter on micro- and nano-scale requires specialized tools that control how components are assembled, when and where they are added, and how the product is transported. Our factory-on-a-chip is designed to do just that. In this project we conduct a two-step assembly process of biological and metallic components in microvesicles of picolitre reaction volumes.
 +
 +
<html>
 +
<img src="https://static.igem.org/mediawiki/2009/4/4b/Anya_rabota_3.jpg" width="700" height="460" border="0" usemap="#map" />
 +
 +
<map name="map">
 +
<!-- #$-:Image map file created by GIMP Image Map plug-in -->
 +
<!-- #$-:GIMP Image Map plug-in by Maurits Rijk -->
 +
<!-- #$-:Please do not edit lines starting with "#$" -->
 +
<!-- #$VERSION:2.3 -->
 +
<!-- #$AUTHOR:Daniel Herde  -->
 +
<area shape="poly" coords="394,332,325,335,289,309,289,206,367,203,391,221" alt="Timer" href="https://2009.igem.org/Team:BIOTEC_Dresden/Notebook_Recombinase" />
 +
<area shape="poly" coords="84,326,42,343,39,282,84,263,100,263,101,200,215,197,215,264,285,259,282,319" alt="Vesicles" href="https://2009.igem.org/Team:BIOTEC_Dresden/Notebook_Vesicles" />
 +
<area shape="poly" coords="40,271,92,252,93,149,30,140" alt="Contact" href="https://2009.igem.org/Team:BIOTEC_Dresden/Contact_v2" />
 +
<area shape="poly" coords="115,184,202,183,201,106,115,109" alt="Modeling" href="https://2009.igem.org/Team:BIOTEC_Dresden/Modeling_v2" />
 +
<area shape="poly" coords="279,163,355,162,351,103,277,105" alt="Team" href="https://2009.igem.org/Team:BIOTEC_Dresden/Team_v2" />
 +
<area shape="poly" coords="386,96,357,113,362,158,391,179,418,150,416,112" alt="Brainstorming" href="https://2009.igem.org/Team:BIOTEC_Dresden/Brainstorm" />
 +
<area shape="poly" coords="668,339,676,239,627,225,625,269,526,272,524,261,506,235,434,236,434,264,408,265,410,319,435,318,463,340,529,339,527,312,631,315,630,321,631,321" alt="Silver Nanoparticles" href="https://2009.igem.org/Team:BIOTEC_Dresden/Notebook_SilverNano" />
 +
<area shape="poly" coords="83,394,90,363,76,344,25,354,6,373,9,445,58,408" alt="Biobricks" href="http://partsregistry.org/cgi/partsdb/pgroup.cgi?pgroup=iGEM2009&amp;amp;group=BIOTEC_Dresden" />
 +
<area shape="poly" coords="595,202,592,122,527,124,529,207" alt="Lab Notebook" href="https://2009.igem.org/Team:BIOTEC_Dresden/Notebook_v2" />
 +
<area shape="poly" coords="698,202,609,219,607,121,695,88" alt="Outreach" href="https://2009.igem.org/Team:BIOTEC_Dresden/Outreach_v2" />
 +
</map>
 +
</html>
 +
Production and packaging in picolitre reactors allows for precise control of all components of the product. The  reactors are vesicles moving through a microfluidic chamber. The transparency of the reactors and flow chamber enables us to monitor the whole production process. Enclosed in the vesicles are a synthetic in-vitro transcription-translation kit, a plasmid coding for a genetic timer and a modified protein, as well as raw materials for silver nanoparticles.
-
{|align="justify"
+
The genetic timer determines the onset of transcription and marks the beginning of the production process. It is a genetic circuit based on Flp recombinase. The timer is set off depending on the distance between two recombination sites. A genetic timer allows to add components sequentially or at a specific time.  
-
|You can write a background of your team here.  Give us a background of your team, the members, etc. Or tell us more about something of your choosing.
+
-
|[[Image:Example_logo.png|200px|right|frame]]
+
-
|-
+
-
|
+
-
''Tell us more about your project.  Give us background.  Use this is the abstract of your projectBe descriptive but concise (1-2 paragraphs)''
+
-
|[[Image:Team.png|right|frame|Your team picture]]
+
-
|-
+
-
|
+
-
|align="center"|[[Team:BIOTEC_Dresden | Team Example]]
+
-
|}
+
-
<!--- The Mission, Experiments --->
+
The protein we express is a GFP tagged with a sequence which is known to nucleate silver nanoparticle formation. An engineer should be able to use any raw material for his product to have the desired properties. Yet traditionally, there is a pronounced distinction between classical and biological engineering. We try to overcome this schism by integrating protein expression and sequence-specific metallization of our modified protein with silver in one manufacturing process.
-
{| style="color:#1b2c8a;background-color:#0c6;" cellpadding="3" cellspacing="1" border="1" bordercolor="#fff" width="62%" align="center"
+
{{:Team:BIOTEC_Dresden/NewTemplateEnd}}
-
!align="center"|[[Team:BIOTEC_Dresden|Home]]
+
-
!align="center"|[[Team:BIOTEC_Dresden/Team|The Team]]
+
-
!align="center"|[[Team:BIOTEC_Dresden/Project|The Project]]
+
-
!align="center"|[[Team:BIOTEC_Dresden/Parts|Parts Submitted to the Registry]]
+
-
!align="center"|[[Team:BIOTEC_Dresden/Modeling|Modeling]]
+
-
!align="center"|[[Team:BIOTEC_Dresden/Notebook|Notebook]]
+
-
|}
+
-
(''Or you can choose different headings.  But you must have a team page, a project page, and a notebook page.'')
+

Latest revision as of 00:39, 22 October 2009


Factory-on-a-chip: Temporal and spatial control of protein synthesis

by in vitro recombination inside picoliter reactors



Organizing matter on micro- and nano-scale requires specialized tools that control how components are assembled, when and where they are added, and how the product is transported. Our factory-on-a-chip is designed to do just that. In this project we conduct a two-step assembly process of biological and metallic components in microvesicles of picolitre reaction volumes.

Timer Vesicles Contact Modeling Team Brainstorming Silver Nanoparticles Biobricks Lab Notebook Outreach

Production and packaging in picolitre reactors allows for precise control of all components of the product. The reactors are vesicles moving through a microfluidic chamber. The transparency of the reactors and flow chamber enables us to monitor the whole production process. Enclosed in the vesicles are a synthetic in-vitro transcription-translation kit, a plasmid coding for a genetic timer and a modified protein, as well as raw materials for silver nanoparticles.

The genetic timer determines the onset of transcription and marks the beginning of the production process. It is a genetic circuit based on Flp recombinase. The timer is set off depending on the distance between two recombination sites. A genetic timer allows to add components sequentially or at a specific time.

The protein we express is a GFP tagged with a sequence which is known to nucleate silver nanoparticle formation. An engineer should be able to use any raw material for his product to have the desired properties. Yet traditionally, there is a pronounced distinction between classical and biological engineering. We try to overcome this schism by integrating protein expression and sequence-specific metallization of our modified protein with silver in one manufacturing process.

Retrieved from "http://2009.igem.org/Team:BIOTEC_Dresden"