Team:PKU Beijing/Parts Characterization/BBa K228004/Transfer
From 2009.igem.org
Spring zhq (Talk | contribs) (→Data) |
|||
Line 21: | Line 21: | ||
==='''Data'''=== | ==='''Data'''=== | ||
- | [[Image:PKU_BBa_K228004_120min.png|400px|center|thumb|Figure 1 - Transfer function of BBa_K228004. This transfer function is the 120 min time-slice from the surface | + | [[Image:PKU_BBa_K228004_120min.png|400px|center|thumb|Figure 1 - Transfer function of BBa_K228004. This transfer function is the 120 min time-slice from the time and dose dependent input-output surface. The data points represent the mean of 6 individual measurements. The corresponding error bars represent the 95% confidence interval in the mean of the independent measurements. The solid black curve was calculated by fitting a simple Hill function to the experimental measurements. The Y axis is the value of fluorescence normalized by the OD600 value, and the X axis is the concentration of the inducer. ]] |
[[Image:PKU_BBa_K228004_All6_new.png|400px|center|thumb|Figure 2 – Transfer functions of BBa_K228004 in different time slices from the time and dose dependent input-output surface. The data points represent the mean of 6 individual measurements. The corresponding error bars denoting the 95% confidence interval in the mean of the independent measurements. These solid curves were calculated by fitting simple Hill functions to the experimental measurements. The Y axis is the value of fluorescence normalized by the OD600 value, and the X axis is the concentration of the inducer. As we can see, the level of induction triggered by the same concentration of inducer (higher than 10^-7 mol/L, causing concentration of 10^-10 mol/L has no significantly positive differences with the blank) will be enhanced as the induction time extended, so it is the same with the saturation. ]] | [[Image:PKU_BBa_K228004_All6_new.png|400px|center|thumb|Figure 2 – Transfer functions of BBa_K228004 in different time slices from the time and dose dependent input-output surface. The data points represent the mean of 6 individual measurements. The corresponding error bars denoting the 95% confidence interval in the mean of the independent measurements. These solid curves were calculated by fitting simple Hill functions to the experimental measurements. The Y axis is the value of fluorescence normalized by the OD600 value, and the X axis is the concentration of the inducer. As we can see, the level of induction triggered by the same concentration of inducer (higher than 10^-7 mol/L, causing concentration of 10^-10 mol/L has no significantly positive differences with the blank) will be enhanced as the induction time extended, so it is the same with the saturation. ]] |
Revision as of 12:10, 19 October 2009
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||