Team:UNICAMP-Brazil/Notebooks/September 21

From 2009.igem.org

(Difference between revisions)
Line 7: Line 7:
====Digested F plasmid's electroelution====
====Digested F plasmid's electroelution====
-
*The digested F plasmid (digested with HindIII) was electroeluted, according to protocol 9. A 110 V voltage was applied during 3h before its extraction from the membrane.
+
*<p style=”text-align:justify;”>The digested F plasmid (digested with HindIII) was electroeluted, according to protocol 9. A 110 V voltage was applied during 3h before its extraction from the membrane.</p>
-
*The next step is to verify if the electroelution went OK. The collected samples of purified plasmid will be applied to a 0,8% agarose gel.
+
*<p style=”text-align:justify;”>The next step is to verify if the electroelution went OK. The collected samples of purified plasmid will be applied to a 0,8% agarose gel.</p>
''Gabriel''
''Gabriel''
Line 14: Line 14:
====finO and finP's biobricks confirmation====
====finO and finP's biobricks confirmation====
-
* We repeated today the PCR's of the minipreps samples, once we now have received new Taq Polymerase enzymes.
+
*<p style=”text-align:justify;”>We repeated today the PCR's of the minipreps samples, once we now have received new Taq Polymerase enzymes.</p>
-
* We run an agarose gel of the reaction products and, according to it, we amplified in a few samples a fragment with the expected size of finO! We couldn't verify this amplification for finP though.
+
*<p style=”text-align:justify;”>We run an agarose gel of the reaction products and, according to it, we amplified in a few samples a fragment with the expected size of finO! We couldn't verify this amplification for finP though.</p>
-
* Nevertheless, we also got several inespecific amplification in almost all samples. We considered that this was caused by the increased amount of genomic DNA we obtained after the miniprep procedure.
+
*<p style=”text-align:justify;”>Nevertheless, we also got several inespecific amplification in almost all samples. We considered that this was caused by the increased amount of genomic DNA we obtained after the miniprep procedure.</p>
-
* Therefore, we will perform another miniprep of the cultures by which we best amplified our expected fragment.
+
*<p style=”text-align:justify;”>Therefore, we will perform another miniprep of the cultures by which we best amplified our expected fragment.</p>
''Marcelo''
''Marcelo''
-
 
-
 
-
 
{{:Team:UNICAMP-Brazil/inc_rodape}}
{{:Team:UNICAMP-Brazil/inc_rodape}}

Revision as of 21:46, 3 October 2009

Topo l2.gif topo_r_igem.gif
topo_r_b.gif
Back to Calendar

ColiGuard

Digested F plasmid's electroelution

  • The digested F plasmid (digested with HindIII) was electroeluted, according to protocol 9. A 110 V voltage was applied during 3h before its extraction from the membrane.

  • The next step is to verify if the electroelution went OK. The collected samples of purified plasmid will be applied to a 0,8% agarose gel.

Gabriel

finO and finP's biobricks confirmation

  • We repeated today the PCR's of the minipreps samples, once we now have received new Taq Polymerase enzymes.

  • We run an agarose gel of the reaction products and, according to it, we amplified in a few samples a fragment with the expected size of finO! We couldn't verify this amplification for finP though.

  • Nevertheless, we also got several inespecific amplification in almost all samples. We considered that this was caused by the increased amount of genomic DNA we obtained after the miniprep procedure.

  • Therefore, we will perform another miniprep of the cultures by which we best amplified our expected fragment.

Marcelo