Team:Paris/Miniprep

From 2009.igem.org

(Difference between revisions)
(Adaptation of PureYieldTM Plasmid Miniprep System (Promega))
(Wash)
Line 16: Line 16:
<br>
<br>
===Wash===
===Wash===
-
plop
+
*Add 200µl of Endotoxin Removal Wash (ERB) to the minicolumn. Allow the vacuum to pull the solution through the column.
 +
*Add 400µl of Column Wash Solution (CWC) to the minicolumn. Allow the vacuum to pull the solution through the column. Release the vacuum, and remove the PureYield(TM) Minicolumn.
 +
*Let dry for 5 minutes. (Preheat Nuclease Free Water at 37°C).
 +
 
 +
===Elute===
 +
*Place the column in a 2ml collection tube, and centrifuge at maximum speed in a microcentrifuge for 2 minutes.
 +
*Transfer the minicolumn into a clean 1.5ml microcentrifuge tube, then add 50µl of hot nuclease-free water directly to the minicolumn matrix. Let stand for 1 minute at room temperature.
 +
*Centrifuge for 1 minute to eluate the plasmid DNA. Cap the microcentrifuge tube, and store eluted plasmid DNA at -20°C.

Revision as of 16:17, 3 August 2009

Contents

Adaptation of PureYield(TM) Plasmid Miniprep System (Promega)

Prepare Lysate

  • Add 2ml of bacterial culture to a 2ml microcentrifuge tube.
  • Centrifuge 1.5ml of bacterial culture for 30 seconds at maximum speed in a microcentrifuge. Discard the supernatant.
  • Add 600µl of H2O (Gibco), and resuspend completely.
  • Add 100µl of Cell Lysis Buffer (Blue), and mix by inverting the tube 6 times.
  • Wait 2min but no more than 5min
  • Add 350µl of cold (4-8°C) Neutralization Solution, and mix thoroughly by inverting.
  • Centrifuge at maximum speed in a microcentrifuge for 10 minutes.
  • Place a PureYield(TM) minicolumn on a Luer-Lok(R) adapter of a VacMan(R).
  • Transfer the supernatant (~900µl) into a PureYield(TM) minicolumn without disturbing the cell debris pellet (yellow-orange).
  • Apply vacuum pulling the lysate through the column.


Wash

  • Add 200µl of Endotoxin Removal Wash (ERB) to the minicolumn. Allow the vacuum to pull the solution through the column.
  • Add 400µl of Column Wash Solution (CWC) to the minicolumn. Allow the vacuum to pull the solution through the column. Release the vacuum, and remove the PureYield(TM) Minicolumn.
  • Let dry for 5 minutes. (Preheat Nuclease Free Water at 37°C).

Elute

  • Place the column in a 2ml collection tube, and centrifuge at maximum speed in a microcentrifuge for 2 minutes.
  • Transfer the minicolumn into a clean 1.5ml microcentrifuge tube, then add 50µl of hot nuclease-free water directly to the minicolumn matrix. Let stand for 1 minute at room temperature.
  • Centrifuge for 1 minute to eluate the plasmid DNA. Cap the microcentrifuge tube, and store eluted plasmid DNA at -20°C.