Team:Paris/Miniprep
From 2009.igem.org
(Difference between revisions)
(→Adaptation of PureYieldTM Plasmid Miniprep System (Promega)) |
(→Wash) |
||
Line 16: | Line 16: | ||
<br> | <br> | ||
===Wash=== | ===Wash=== | ||
- | + | *Add 200µl of Endotoxin Removal Wash (ERB) to the minicolumn. Allow the vacuum to pull the solution through the column. | |
+ | *Add 400µl of Column Wash Solution (CWC) to the minicolumn. Allow the vacuum to pull the solution through the column. Release the vacuum, and remove the PureYield(TM) Minicolumn. | ||
+ | *Let dry for 5 minutes. (Preheat Nuclease Free Water at 37°C). | ||
+ | |||
+ | ===Elute=== | ||
+ | *Place the column in a 2ml collection tube, and centrifuge at maximum speed in a microcentrifuge for 2 minutes. | ||
+ | *Transfer the minicolumn into a clean 1.5ml microcentrifuge tube, then add 50µl of hot nuclease-free water directly to the minicolumn matrix. Let stand for 1 minute at room temperature. | ||
+ | *Centrifuge for 1 minute to eluate the plasmid DNA. Cap the microcentrifuge tube, and store eluted plasmid DNA at -20°C. |
Revision as of 16:17, 3 August 2009
Contents |
Adaptation of PureYield(TM) Plasmid Miniprep System (Promega)
Prepare Lysate
- Add 2ml of bacterial culture to a 2ml microcentrifuge tube.
- Centrifuge 1.5ml of bacterial culture for 30 seconds at maximum speed in a microcentrifuge. Discard the supernatant.
- Add 600µl of H2O (Gibco), and resuspend completely.
- Add 100µl of Cell Lysis Buffer (Blue), and mix by inverting the tube 6 times.
- Wait 2min but no more than 5min
- Add 350µl of cold (4-8°C) Neutralization Solution, and mix thoroughly by inverting.
- Centrifuge at maximum speed in a microcentrifuge for 10 minutes.
- Place a PureYield(TM) minicolumn on a Luer-Lok(R) adapter of a VacMan(R).
- Transfer the supernatant (~900µl) into a PureYield(TM) minicolumn without disturbing the cell debris pellet (yellow-orange).
- Apply vacuum pulling the lysate through the column.
Wash
- Add 200µl of Endotoxin Removal Wash (ERB) to the minicolumn. Allow the vacuum to pull the solution through the column.
- Add 400µl of Column Wash Solution (CWC) to the minicolumn. Allow the vacuum to pull the solution through the column. Release the vacuum, and remove the PureYield(TM) Minicolumn.
- Let dry for 5 minutes. (Preheat Nuclease Free Water at 37°C).
Elute
- Place the column in a 2ml collection tube, and centrifuge at maximum speed in a microcentrifuge for 2 minutes.
- Transfer the minicolumn into a clean 1.5ml microcentrifuge tube, then add 50µl of hot nuclease-free water directly to the minicolumn matrix. Let stand for 1 minute at room temperature.
- Centrifuge for 1 minute to eluate the plasmid DNA. Cap the microcentrifuge tube, and store eluted plasmid DNA at -20°C.